RC and RL time constants: the 63 percent rule
A resistor and a capacitor, or a resistor and an inductor, form a first-order circuit with one energy store. Its response to a step is exponential, and a single number, the time constant τ, sets the speed. For a capacitor τ = RC; for an inductor τ = L/R.
RC: v(t) = V(1 − e^(−t/τ)), τ = RC · RL: i(t) = I(1 − e^(−t/τ)), τ = L/R
Where the formula comes from
For a capacitor charging through R from a supply V, Kirchhoff's voltage law gives V = Ri + v with i = C dv/dt, so RC dv/dt + v = V. The solution with v(0) = 0 is the exponential above. The same equation appears for inductor current with L/R in place of RC, because both describe one store losing or gaining energy through one resistor.
The time constant is the time to reach 63.2 percent of the final change. After 2τ it is 86.5 percent, 3τ 95.0 percent, 4τ 98.2 percent, 5τ 99.3 percent. These figures are worth knowing because they convert a measured rise time into a component value without a calculator: a rise to 63 percent in 2.2 ms means τ = 2.2 ms.
Sizing a delay
Suppose a reset line must stay low for at least 100 ms after power-up. Choose 5τ ≈ 100 ms, so τ = 20 ms. With C = 1 µF, R = τ/C = 20 kΩ. With C = 10 µF, R = 2 kΩ. The capacitor tolerances and the input threshold spread matter more than the exact exponential, so pick R with a comfortable margin and check the threshold, typically 0.5 to 0.7 of the supply for a CMOS input.
For an inductor, τ = L/R. A 100 mH relay coil with 100 Ω resistance has τ = 1 ms. Its current reaches 63 percent in 1 ms and the magnetic field follows. When the drive is removed, the collapsing field generates a large negative voltage unless a flyback diode or a snubber is fitted; the diode path changes the fall time to roughly L/Rcoil in parallel with the diode's forward behaviour.
The same circuit as a filter
The RC low-pass has a cutoff at fc = 1/(2πRC), where the output falls to 0.707 of the input, or −3 dB. With R = 10 kΩ and C = 100 µF, τ = 1.0 s and fc = 0.159 Hz. With R = 1 kΩ and C = 100 nF, τ = 100 µs and fc = 1.59 kHz. The product RC fixes both the step response and the frequency response; you cannot change one without the other.
The RL low-pass is the dual: fc = R/(2πL). A 100 mH inductor with 10 Ω gives τ = 10 ms and fc = 15.9 Hz. Inductors are bulkier and lossier at low frequencies, so RC filters dominate below a few megahertz, while RL and LC filters take over where low loss matters.
Reading the response correctly
The initial slope of an exponential, if continued, reaches the final value at exactly t = τ. That is a quick graphical check: draw the tangent at t = 0 and see where it crosses the asymptote. The tangent method also shows why the response never overshoots in a first-order system: there is no second store to exchange energy with.
If a measured step response does overshoot or ring, the circuit is at least second order. Stray capacitance across an inductor, or inductance in a capacitor lead, adds the missing store. The series RLC page shows the boundary: with R large enough the response is overdamped and looks first order; as R falls, ringing appears at f₀ and the damping ratio ζ = (R/2)√(C/L) predicts how much.
Practical checks
Measure R after the capacitor, not before: a capacitor's leakage and dielectric absorption can make a slow tail that a simple exponential misses. Keep the time constant well away from the sampling interval of any digital measurement, at least ten samples per τ, or the peak you record will be wrong. And remember that a 10× probe and a 100 MHz scope still load a fast RC node; the probe capacitance adds to C and slows the response you are trying to measure.
Dielectric absorption makes a capacitor recover some voltage after being discharged. It is not modelled by τ = RC and matters in sample-and-hold and precision integrator circuits.
Questions
Why 63.2 percent and not 50 percent?
The response is exponential, e^(−t/τ), not linear. At t = τ the remaining difference has fallen to 1/e = 36.8 percent, so 63.2 percent of the change has happened. Reaching 50 percent takes 0.693τ.
Is 5τ exact settling?
No. At 5τ the remaining error is e⁻⁵ = 0.67 percent, and at 7τ it is 0.09 percent. Five time constants is a common engineering convention for 'settled', not a mathematical endpoint.
The RLC page shows the same first-order behaviour in the low and high frequency tails of its Bode plot.
Open the simulatorWritten from standard electromagnetic theory and AC circuit analysis; the worked numbers can be reproduced in the simulator linked above.
Back to the guides