Bode plots and decibels: reading gain and phase at a glance
A Bode plot shows the magnitude and the phase of a transfer function against frequency, with frequency on a logarithmic axis. Magnitude is usually in decibels: dB = 20 log₁₀|H|. A gain of 1 is 0 dB, 2 is +6.02 dB, 10 is +20 dB, 0.5 is −6.02 dB and 0.707 is −3.01 dB.
|H|_dB = 20 log₁₀|H| · −3 dB ⇔ |H| = 1/√2 = 0.707
Why 20 and not 10
Power ratio in decibels is 10 log₁₀(P₂/P₁). For a fixed resistance, power is proportional to voltage squared, so a voltage ratio gives 10 log₁₀(V₂²/V₁²) = 20 log₁₀(V₂/V₁). Both conventions describe the same physical ratio; the factor differs because the quantity being compared differs.
The decibel is convenient because a cascaded chain multiplies gains, and in dB the gains simply add. An amplifier with 20 dB gain followed by a filter with −3 dB loss gives 17 dB overall. A dynamic range from 1 µV to 1 V is 120 dB, a single readable number.
First-order asymptotes
An RC low-pass has H(f) = 1/(1 + jf/fc). Below fc the gain is close to 0 dB. At fc it is −3.01 dB and the phase is −45°. A decade above fc the gain is about −20 dB and the phase approaches −90°. The magnitude asymptote falls at 20 dB per decade, or 6 dB per octave.
A first-order high-pass is the mirror image: −20 dB per decade below fc, 0 dB above, phase +90° at low frequency and 0° high. An RL filter has the same shape with fc = R/(2πL). The slope order equals the number of independent energy stores: two stores give 40 dB per decade far from resonance, three give 60.
The resonant case
The series RLC response plotted on the RLC page is a second-order bandpass. Far below f₀ the capacitor dominates and the slope is +20 dB per decade; far above, the inductor dominates and the slope is −20 dB per decade. Near f₀ the response peaks at 0 dB for the normalised transfer used here, and the width between the −3 dB points is the bandwidth.
Phase runs from +90° at low frequency, through 0° at f₀, to −90° at high frequency. The steeper the phase transition, the higher the Q. A high-Q circuit changes phase rapidly around f₀, which is why oscillator and PLL loops care about the phase slope as much as the magnitude.
Reading the plot without a calculator
Two rules cover most reading. A factor of 2 in frequency is about 0.301 decades, so a 20 dB/decade slope is about 6 dB per octave. A factor of 10 in gain is 20 dB, a factor of 100 is 40 dB. To find a −3 dB point, look for where the curve is 3 dB below its flat region, not where it crosses some absolute value.
Watch the axis labels. A plot with a linear frequency axis hides the low-frequency behaviour and makes a first-order roll-off look like a curve rather than a straight line. A plot without a marked 0 dB reference makes it easy to read a gain of 0.5 as a passband. The reference line and the log axis are part of the measurement.
Where the model stops
The straight-line asymptotes are idealisations. Real inductors have self-capacitance that adds a high-frequency pole, real capacitors have ESR that adds a zero, and stray capacitance to ground adds poles you did not design. Above a few megahertz, a measured Bode plot usually diverges from the two-component model.
The measurement setup matters too. A network analyser calibrates out its own source and load impedance; a quick measurement with a function generator and an oscilloscope does not. If the source impedance is comparable to the circuit impedance, the plotted response includes the divider formed by the source, and the −3 dB point moves. State the source and load conditions with every Bode plot you publish.
The simulator normalises the series response to 0 dB at resonance so that Q and bandwidth are easy to read. Absolute gain in a real circuit also depends on where the load is connected.
Questions
Why use decibels instead of a plain ratio?
Decibels turn multiplication into addition and compress a huge dynamic range into a manageable scale. A gain of 1000 is 60 dB, 0.001 is −60 dB, and cascaded stages add their dB values. Plotting on a log frequency axis with a dB vertical axis makes straight-line asymptotes visible.
Is the −3 dB point the same as the cutoff frequency?
For a first-order low-pass or high-pass filter, yes. It is the frequency where the output power is half the passband value, the voltage is 1/√2, and the phase has moved 45°. For higher-order or resonant responses there can be several such points.
The Bode panel plots magnitude and phase from 1/1000 to 1000 times f₀ in one view.
Open the simulatorWritten from standard electromagnetic theory and AC circuit analysis; the worked numbers can be reproduced in the simulator linked above.
Back to the guides