opyeb EMLab

Guides · Resonance

Parallel RLC and the tank circuit: high impedance at resonance

Updated 28 Nov 2026 · 7 min read

Put R, L and C in parallel and drive them from a current source, or from a voltage source through a large resistance. The admittance is Y = 1/R + j(ωC − 1/(ωL)). At the frequency where the susceptances cancel, the admittance is just 1/R, so the impedance is maximum and equal to R. The same f₀ = 1/(2π√(LC)) applies.

The difference from the series case is what happens to the current. In series resonance the source current is maximum and the reactor voltages are large. In parallel resonance the source current is minimum and the current circulating between L and C is Q times larger. The two are dual descriptions of the same energy exchange.

f₀ = 1/(2π√(LC))   ·   Q = R√(C/L)   ·   BW = f₀/Q   ·   Z(f₀) = R

The numbers, with the same components

Using L = 100 mH and C = 10 µF again gives f₀ = 159.15 Hz. Now choose R = 10 kΩ. The quality factor is Q = R√(C/L) = 10 000 × √(10⁻⁵/0.1) = 10 000 × 0.01 = 100. The bandwidth is 1.59 Hz, ten times narrower than the series case with R = 10 Ω, because Q is ten times higher.

At resonance the impedance is 10 kΩ. Off resonance it falls: at 100 Hz the admittance is 1/10 000 + j(2π×100×10⁻⁵ − 1/(2π×100×0.1)) = 10⁻⁴ + j(0.00628 − 0.01592) = 10⁻⁴ − j0.00964 S, so |Z| ≈ 103.7 Ω. A small frequency error collapses the impedance by a factor of nearly 100, which is exactly what makes a tank useful as a filter and awkward as a wideband load.

Circulating current

At resonance the current through the inductor is V/(ω₀L) and through the capacitor is Vω₀C, equal in magnitude and opposite in phase. With V = 100 V RMS, ω₀ = 1000 rad/s and L = 100 mH, each is 1 A, while the source supplies only V/R = 10 mA. The tank circulates 100 times the source current. Inductor and capacitor must be rated for that circulating current, and the coil's resistance is the main loss.

Real inductors have winding resistance r in series with L. At resonance the equivalent parallel resistance is approximately Rp = Q²r, so a coil with Q = 100 and r = 1 Ω looks like 10 kΩ. This transformation is why a physical tank can have a high impedance even though the coil itself is a low-resistance element.

Where the resistor sits matters

The formula Q = R√(C/L) assumes R is in parallel with an ideal L and C. If the only loss is the coil resistance in series with L, the correct expression is Q = ω₀L/r, and the resonant frequency is shifted to f₀ = (1/2π)√(1/(LC) − (r/L)²). For high Q the shift is negligible; for Q below about 10 it is not.

The simulator's parallel mode uses the ideal parallel resistor model, so its readouts follow Q = R√(C/L) exactly. When comparing with a real coil, convert the series resistance to its parallel equivalent first, or use the series model with the same component values and accept that the circuit topology is different.

Applications and traps

Tanks are used as the load of an RF amplifier, as the tuning element in oscillators, and as notch filters. In each case the high impedance at f₀ provides gain or rejection while the low impedance elsewhere shunts unwanted frequencies. The narrower the bandwidth, the more selective, and the more sensitive to component drift.

The classic trap is the parallel resonance of a power factor correction capacitor with the supply transformer inductance. At the resonant frequency the impedance seen by a harmonic current is high, so a small harmonic current produces a large voltage, and the capacitor carries a large circulating current. Detuning reactors and harmonic filters exist to move that resonance away from the harmonics the load generates.

A second trap is measurement. A signal generator with a 50 Ω output driving a high-impedance tank forms a divider that changes the loaded Q. The unloaded Q of the tank may be 100, while the Q you measure with a 50 Ω source can be far lower. Always state the source and load impedance with a measured Q.

For the ideal parallel model the impedance at resonance is exactly R. With a real coil, the maximum impedance occurs slightly below the frequency where the phase is zero when Q is low.

Questions

Why is parallel resonance called antiresonance?

Because the current through the source is minimum while the circulating current between the reactor and capacitor is large. The terminal behaviour is the opposite of series resonance, where the source current peaks.

Does the same f₀ formula apply?

For the ideal parallel combination of an inductor, a capacitor and a resistor, yes: f₀ = 1/(2π√(LC)). If the resistor is in series with the inductor instead, the resonant frequency shifts slightly; the difference matters when Q is low.

Switch the RLC page to parallel mode and compare the impedance peak with the series case.

Open the simulator

Written from standard electromagnetic theory and AC circuit analysis; the worked numbers can be reproduced in the simulator linked above.

Back to the guides