Transmission lines and the Smith chart without the mystery
At low frequencies a wire is a wire. At high frequencies the time a wave takes to travel along it becomes comparable to the signal's own period, and the line must be treated as a distributed system with a characteristic impedance Z₀. For a lossless line, Z₀ = √(L'/C'), where L' and C' are inductance and capacitance per metre.
When a wave reaches a load that is not equal to Z₀, part of it reflects. The reflection coefficient is Γ = (Z_L − Z₀)/(Z_L + Z₀). It is a complex number: its magnitude gives how much is reflected, and its angle gives the phase. A short circuit gives Γ = −1, an open circuit Γ = +1, and a matched load gives Γ = 0.
Γ = (Z_L − Z₀)/(Z_L + Z₀) · VSWR = (1 + |Γ|)/(1 − |Γ|) · RL = −20 log₁₀|Γ|
A 75 Ω load on a 50 Ω line
Γ = (75 − 50)/(75 + 50) = 25/125 = 0.20 at 0°. The VSWR is (1 + 0.2)/(1 − 0.2) = 1.5. The return loss is −20 log₁₀(0.2) = 13.98 dB. About 4 percent of the incident power is reflected and 96 percent reaches the load, which is why a 1.5:1 VSWR is usually acceptable.
For a complex load, say 25 − j50 Ω on a 50 Ω line, Γ = (−25 − j50)/(75 − j50). The magnitude is √(625 + 2500)/√(5625 + 2500) = 55.9/90.1 = 0.620, and the angle is about −83°. The VSWR is 4.27 and the return loss 4.15 dB: nearly 39 percent of the power is reflected. A complex load is not automatically worse than a real one — what matters is the distance from Z₀ in the complex plane.
Impedance along the line
The input impedance of a line of length l terminated in Z_L is Z_in = Z₀(1 + Γe^(−2jβl))/(1 − Γe^(−2jβl)), with β = 2π/λ. Moving along the line rotates Γ clockwise by 2βl, one full turn per half wavelength. The magnitude of Γ does not change on a lossless line, so the impedance traces a circle centred on the chart's origin: the VSWR circle.
A quarter-wavelength line is the special case worth memorising: Z_in = Z₀²/Z_L. A 75 Ω load on a 50 Ω quarter-wave line presents 33.3 Ω at the input. This impedance inversion is the basis of quarter-wave matching sections and of the way a shorted stub can look like an open circuit.
The Smith chart as a picture of Γ
The Smith chart is a polar plot of Γ with the impedance grid drawn on it. Constant resistance becomes circles tangent to the right-hand point, constant reactance becomes arcs, and the unit circle is the boundary |Γ| = 1 where reactive loads sit. The centre is a perfect match; the right edge is an open circuit; the left edge is a short.
Normalise the load by Z₀, find the intersection of the resistance circle and reactance arc, and read Γ directly. Then move along the line by rotating clockwise around the centre by the electrical length. The Smith page draws the normalised point, the VSWR circle and a line to the rotated input point, so the geometry matches the formula.
Wavelength and physical length
The wavelength on a line is λ = v/f = c·vf/f, where vf is the velocity factor, typically 0.66 for solid polyethylene coax and 0.8 to 0.9 for foam. At 100 MHz with vf = 0.66, λ = 3 × 10⁸ × 0.66 / 10⁸ = 1.98 m. A quarter wave is 0.495 m. Electrical length in degrees is 360 × l/λ.
This is why cable length matters at RF and not at audio: 0.5 m of coax at 100 MHz is about 91 electrical degrees, a substantial rotation, while at 1 kHz it is 0.0006 degrees. The same physical cable is a transmission line or a wire depending on the frequency.
Loss, and what the ideal model leaves out
Real lines have conductor and dielectric loss, so Γ shrinks as it travels and the VSWR circle spirals inward. The characteristic impedance also has a small imaginary part. Attenuation is quoted in dB per 100 m at a specified frequency, and it rises with frequency because of skin effect and dielectric loss.
The ideal model here assumes a uniform line, a single frequency and a linear termination. It does not cover dispersion, connectors with their own impedance bumps, or baluns. Those are best handled by measurement: a vector network analyser sweeps frequency, calibrates at the reference plane, and produces the actual Γ and Z_in, which can then be compared with the model.
Return loss is a positive number in dB: higher is better. Reflection coefficient magnitude and VSWR say the same thing in different units; none of them says where the reflection comes from without a time-domain measurement.
Questions
What is a good VSWR?
Below 1.5:1 is generally good, below 2:1 is usually acceptable, and above 3:1 indicates a significant mismatch. The right limit depends on the system: a receiver front end may care about 1.2:1, while a rugged industrial link may work at 2:1.
Does a matched line have no reflection at all?
At the load, yes: if ZL = Z0 the reflection coefficient is zero. Reflections can still arise from connectors, bends and imperfect terminations along the line. 'Matched' is a property of a specific interface, not a guarantee for a whole system.
The Smith page draws the reflection point, the VSWR circle and the rotation along the line.
Open the simulatorWritten from standard electromagnetic theory and AC circuit analysis; the worked numbers can be reproduced in the simulator linked above.